Okay, Houston, we've had a problem here. This is Houston. Say again, please. Houston, we've had a problem. We've had a main beam plus undervolt. Roger, main beam undervolt. Okay, standby at 13. We're looking at it. Okay, right now, Houston, the voltage is looking good. And we had a pretty large bang associated with the caution and warning there. And as I recall, BP was the one that had an amp spike on it once before. Roger, Fred. In the interim here, we're starting to go ahead and button up the tunnel again. Roger. Yeah, that jolt must have rocked the sensor. I see now an O2 quantity two. It was oscillating down around 20 to 60 percent. Now it's full scale high again. Roger. And, Houston, we have a restart on our computer. We have a ping slide and a restart reset. Roger, restart and a ping slide. Restart and a ping slide reset. Okay, and we're looking at our surface module RTS UAM1. We have B as bubble pool and D as bubble pool. UAM2, D as bubble pool. And secondary propellant, so I have A and C bubble pool. TMAG temperatures. Okay, AC2, Sean. I'm trying to reconfigure on that, Jack. Roger. Yeah, we got a main A undervolt now too, Sean. Main A undervolt. It's reading to about 25 and a half. Main B's reading zip right now. Stand by one, Jim. 13, Houston, we'd like you to attempt to reconnect fuel cell one to main A and fuel cell three to main B. Verify that quad delta is open. Okay, Houston, I'm Sean. I tried to reset fuel cell one and three. They're both showing gray flags. But they're both showing zip on the flows. We copy. 13, Houston, we'd like you to open circuit fuel cell one. Leave two and three as is. Okay, I'll get to work on that. Can I listen to you? You're looking out the hatch, so we are venting something. We are venting something out into the space. Roger, we copy your venting. It's a gas fuel cell.